บริการลูกค้า 09 9824 5451
Electrical stroke | mm | 25 | 50 | 75 | 100 | 125 | 150 | 175 | 200 |
Resistance±10% | kΩ | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Independent linearity: | |||||||||
guaranteed | ±% | 0.25 | 0.25 | 0.15 | 0.15 | 0.15 | 0.15 | 0.15 | 0.15 |
typical | ±% | 0.15 | 0.15 | 0.15 | 0.10 | 0.10 | 0.07 | 0.07 | 0.07 |
Power dissipation at 20 ̊C | W | 0.5 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 |
Applied voltage (max) | Vdc | 22 | 44 | 67 | 74 | 74 | 74 | 74 | 74 |
Electrical Output | Minimum of 0.5% to 99.5% applied volts | ||||||||
Resolution | Virtually Infinite | ||||||||
Hysteresis | Less than 0.01mm | ||||||||
Operational Temperature | °C | –30 to +100 (tested to +130 for 12 hours duration) |
Hybrid track potentiometers feature a high wiper contact resistance, therefore operational checks should be carried out only in the voltage divider mode. Hybrid track potentiometers should be used only as voltage dividers, with a minimum wiper circuit impedance of 100 x track resistance or 0.5MΩ (whichever is greater). Operation with wiper circuits of lower impedance will degrade the output smoothness and affect the linearity.