E112 Linear Position Sensor

The intrinsically safe E112 is ATEX and IECEx approved for use in potentially explosive gas/vapour and dust atmospheres. It is designed for gauge head positioning in industrial and scientific applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas.
The E112, like all Positek® sensors, provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-50mm and with full EMC protection built in.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is very robust, the body and plunger being made of stainless steel for long service life and environmental resistance. The plunger is spring loaded with a domed end. The E112 is easy to install with a long ½ inch UNF mounting thread and is supplied with two lock nuts for positioning. Environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

View all Linear Sensors

 

Description

The Positek gauge head E112 linear position sensor is ATEX and IECEx approved for use in potentially explosive gas/vapour and dust atmospheres. It is designed for gauge head positioning in industrial and scientific applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas.
The E112 gauge head sensor, like all Positek® sensors, provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-50mm and with full EMC protection built in.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is very robust, the body and plunger being made of stainless steel for long service life and environmental resistance. The plunger is spring loaded with a domed end. The E112 is easy to install with a long ½ inch UNF mounting thread and is supplied with two lock nuts for positioning. Environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Follow us on Facebook

Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:

 

Measurement Range

Factory set to any length from 0-5mm to 0-50mm in increments of 1mm. For example, if your application requires 3/4" (19 mm) measurement, then Positek will manufacture the sensor specifically for this length. The mechanical length and calibration will be set up for 19 mm.

 

 

Connector/Cable Options

Option Option Code
Connector - Axial IP67, M12 - 4 pin J
Connector - Radial IP67, M12 - 4 pin K
Cable with PG9 gland Axial, IP67 L (3 core cable)
LQ (5 core cable)
Cable length - The standard length of cable supplied with a Positek position sensor is 50cm although you can specify any length you require. Specified in cm after the L/LQ e.g. L200 for 200cm 3 core cable from axial cable gland

 

<+/-0.1% FSO Linearity error (10mm minimum stroke length) Option Code
Z650

Intrinsic Safety

ATEX/IECEx approval

The sensor is ATEX/ IECEx approved to:
Ex II 1GD
Ex ia IIC T4 Ga (Ta = -40°C to + 80°C )
Ex ia 111C T135°C Da (Ta = -40°C to + 80°C ).
This designates the sensor as belonging to; Group II: suitable for all areas except mining, Category 1 GD: can be used in areas with continuous, long or frequent periods of exposure to hazardous gas (Zones 2 to 0) and dust (Zone 20).

Gas:
Protection class ia, denotes intrinsically safe for all zones.
Apparatus group IIC: suitable for IIA, IIB and IIC
explosive gases.
Temperature class T4: maximum sensor surface
temperature under fault conditions 135°C .

Dust:
T135°C: maximum sensor surface temperature under
fault conditions 135°C .
Ambient temperature range extended to -40°C to +80°C .

Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.

Galvanic Isolation Amplifier

Intrinsically safe sensors must be used with a galvanically isolated amplifier with safety parameters not exceeding:- Ui: 11.4V, Ii: 0.2A, Pi: 0.51W.  Sensor can be installed with a cable length up to 1000m maximum from the amplifier, cable capacitance and inductance can be up to:- Capacitance: 200 nF max, Inductance: 810 µH max.

Approved amplifiers are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs. 

 

Dimensions

Body Diameter 19mm
Body Length (excluding thread) Axial version: 160.7mm
Radial version: 169.5mm
Mounting Thread Length 59mm
Spring Force 1.5-4.5N (approximately)
Travel Any stroke from 0-5mm to 0-50mm (e.g. 19mm)
Independent Linearity <±0.25% at 20°C 
<±0.1% available on request
Temperature Coefficient <±0.01%/°C Gain & <±0.01%FS/°C Offset
Resolution Infinite
Noise

<0.02% FSO

Frequency Response

>10KHz (-3dB)

 

Temperature Limits

Operating -40 to +80°C
Storage -40 to +125°C

 

Other

EMC Susceptibility EN 61000-6-2
EMC Radiated EN 61000-6-3
Vibration IEC 68-2-6: 10g
Shock IEC 68-2-29: 40g
MTBF 350,000 hrs 40°C Gf
Sealing IP67
Electrical Connections Screened cable or integral connector